Normal or not? Sights, sounds and smells

Heat pumps and air conditioners make noises, drip and sometimes steam. Most of it is part of how they work. Here's how to tell what's fine from what needs a call.

What you're seeing or hearing

General guidance for heat pumps, air conditioners and furnaces. If in doubt, switch the system off and call us.

  • Normal

    Heating

    Steam rising from the outdoor unit

    A defrost cycle on a cold morning. The unit melts the frost off its coil, and the melt turns to steam. It stops within a few minutes.

  • Normal

    Heating

    Outdoor fan stops, then a whoosh

    Also defrost. The valve switching over makes a whoosh; the fan restarts when it's done.

  • Normal

    Heating

    Warm air, not hot

    A heat pump delivers warm air for longer, rather than short blasts of hot air like a gas furnace. It still heats the room.

  • Normal

    Heating

    Dusty smell on the first cold day

    Dust burning off the heater after months unused. It should fade within an hour or so.

  • Normal

    Cooling

    Water dripping from a pipe outside

    Condensate — moisture pulled out of your indoor air. A steady drip from the drain line on a warm day is what it should do.

  • Normal

    Cooling

    Warm air blowing out of the outdoor unit

    That's the heat taken out of your home being released outside.

  • Normal

    Any season

    A click, then the fan starting

    Relays and the thermostat switching on. A single click at start and stop is expected.

  • Call

    Cooling

    Ice on the indoor unit or copper lines

    Usually low airflow or low refrigerant. Switch cooling off, leave the fan on to thaw, and call us.

  • Call

    Heating

    Outdoor unit covered in ice for hours

    Light frost is normal. A block of ice that never clears means defrost isn't working.

  • Call

    Any season

    Water pooling indoors

    Around the furnace, air handler or under a wall unit. Usually a blocked or broken drain — turn the system off to limit damage.

  • Call

    Any season

    Grinding, screeching or banging

    Moving parts rubbing or loose. Switch off before a small repair becomes a motor or compressor.

  • Call

    Any season

    Burning plastic or electrical smell

    Unlike the first-day dust smell, this doesn't fade. Turn the system off at the thermostat and the breaker.

  • Call

    Any season

    Starts and stops every few minutes

    Short cycling wears equipment out fast. Often a thermostat, sensor, airflow or sizing problem.

  • Call

    Any season

    The breaker keeps tripping

    Don't keep resetting it. Leave it off and call us.

Smell gas? Leave first.

A rotten-egg smell near a furnace, water heater or stove is not a service call. Get everyone outside, don't switch anything on or off, and call the gas company or 911 from outside. We can repair the appliance once it has been made safe.

Light steam rising from a heat pump outdoor unit on a cold morning during a defrost cycle
Steam during a defrost cycle — normal.
Water dripping from a white condensate drain pipe beside an air conditioner
Condensate dripping outside in summer — normal.